Explosion-proof Motor Selection

The selection of explosion-proof motors must follow the following principles.

1. Explosion-proof motor selection principle

The choice of explosion-proof motors must be compatible with the hazard of the explosive mixture. The so-called dangerous degree of explosive mixture refers to the group of explosion level and ignition temperature of explosive mixture. The selected explosion-proof electrical equipment must be compatible with the explosion level, group, and level of the hazardous area of ​​the explosive mixture, otherwise safety cannot be guaranteed. In addition, if there are two or more explosive substances with different danger levels in the same area, an explosion-proof structure that is compatible with the explosion level and natural temperature level with a high degree of danger must be selected. In non-hazardous areas, ordinary electrical equipment is generally used. However, when containers containing explosive substances are placed in non-hazardous areas, there is also the possibility of danger under abnormal conditions. For example, dangerous substances are spilled due to corrosion of containers, or dangerous substances are released due to mishandling by operators, or high temperature and high pressure are formed due to abnormal reactions, which damage devices and containers and leak explosive substances. Therefore, the possibility of accidental hazards must be considered.

Explosion-proof Motor Selection

Request A Quote

2. Choose the right type of explosion protection

The choice of explosion-proof construction must be suitable for use in hazardous areas. What kind of explosion-proof structure must be used in the hazardous area of ​​what nature. The explosion-proof performance is different due to different structures, so the appropriate explosion-proof type must be selected according to the type of explosive substances, the type of equipment, and the degree of danger of the installation site.

3. adapted to environmental conditions

The explosion-proof performance mentioned in this article is based on the standard environment as the basic condition. Explosion-proof equipment can be divided into “indoor use” and “outdoor use”. Equipment used indoors is not suitable for outdoor use with an ambient temperature of 40°C. Equipment used outdoors should be adapted to the open-air environment, and measures such as sun protection, rain and wind and sand should be taken. In addition, some equipment is used in corrosive or toxic environments, high temperature, high pressure or low temperature environments, and when selecting explosion-proof equipment, special requirements to adapt to these special environments should be considered.

4. For easy maintenance

Maintenance and care during use of explosion-proof motors is extremely important. The simpler the structure of explosion-proof electrical equipment, the better. At the same time, pay attention to convenient management, short maintenance time, low cost, and normal storage of spare parts and spare parts.

5. Pay attention to economic benefits

When choosing an explosion-proof motor, not only the purchase and sale price should be considered, but also a comprehensive analysis and balance of the reliability, life, operating cost, energy consumption and maintenance of the explosion-proof motor to choose a suitable and economical explosion-proof motor.


Post time: 2022-02-14
  • Previous:
  • Next:
  • Tags:

  • Write your message here and send it to us
    Related Posts
    • Causes Of High Motor Current
      Causes Of High Motor Current

      Several situations of motor current being too high When the motor current is high, it is often manifested in the serious heating of the motor. The following basically summarizes the reason why the motor current is too high. 1. The power supply voltage is too high When the power supply voltage is too high, the …

    • Features Of Large And Medium-Sized Motor
      Features Of Large And Medium-Sized Motor

      (1) Large and medium-sized motors need to be customized Different from the standardized design and production process of micro-motors, low-power motors and small-sized motors, large and medium-sized motors need to meet customer requirements for rated power, speed, voltage, bearing form, cooling method, protection level, torque characteristics, overload capacity, Dozens of parameters such as load characteristics, …

    • Common Faults Of High-Voltage Explosion-Proof Motors
      Common Faults Of High-Voltage Explosion-Proof Motors

      The faults of high-voltage explosion-proof motors can be divided into electrical faults and machine faults. The important faults in the machine are vibration, bearing overheating, rotor sweeping, abnormal running sound, etc.; in the electrical field, if the motor winding is grounded, short-circuited, open circuit, bad contact, squirrel cage broken and other faults. The insulation failure …

    • Explosion-proof Motor Selection
      Explosion-proof Motor Selection

      The selection of explosion-proof motors must follow the following principles. 1. Explosion-proof motor selection principle The choice of explosion-proof motors must be compatible with the hazard of the explosive mixture. The so-called dangerous degree of explosive mixture refers to the group of explosion level and ignition temperature of explosive mixture. The selected explosion-proof electrical equipment …

    • The Difference Between Explosion-Proof Motor And Ordinary Motor
      The Difference Between Explosion-Proof Motor And Ordinary Motor

      What is the difference between explosion-proof motors and ordinary motors? 1. Explosion-proof motors are generally used in flammable and explosive situations 2. The sealing of explosion-proof motor junction box is better than that of ordinary motors 3. The low protection level of explosion-proof motors is IP55, while ordinary motors have IP23, IP44, IP54, IP55, and …

    • Maintenance Of Explosion-proof Motors
      Maintenance Of Explosion-proof Motors

      Explosion-proof motors are widely used in flammable and explosive dangerous places, including explosive gas environment, combustible dust environment and fire hazard environment, etc., mainly used in coal mines, oil and gas, petrochemical and chemical industries. In addition, it is also widely used in textile, metallurgy, urban gas, transportation, grain and oil processing, papermaking, medicine and …

    • Matching Selection Of Inverter And Motor
      Matching Selection Of Inverter And Motor

      According to the load characteristics of the drive equipment, it is divided into three types: constant power load, constant torque load and fan pump load. Different load types have different requirements on the inverter. Constant power load The torque required by the spindle of the machine tool and the coiler and uncoiler in the rolling …

    • The Difference Between Ordinary Motor And Variable Frequency Motor
      The Difference Between Ordinary Motor And Variable Frequency Motor

      1. Ordinary asynchronous motors are designed according to constant frequency and constant voltage, and it is impossible to fully meet the requirements of variable frequency speed regulation. The following is the influence of the inverter on the motor (1) The efficiency and temperature rise of the motor Regardless of the type of frequency converter, different …

    • Motor Speed And Slip
      Motor Speed And Slip

      The unit of rotation speed is r/m (rpm) per minute and r/s (rps) per second. ① Synchronous speed of the motor Because the rotation of the induction motor comes from the action of the rotating magnetic field, its speed is the same as that of the rotating magnetic field, so the synchronous speed of the …

    • Abnormal Sound Of Motor Bearing
      Abnormal Sound Of Motor Bearing

      Common causes of abnormal bearing noise: 1. Impurities such as sand or carbon particles are mixed into the bearing, which acts as an abrasive; 2. The bearing is mixed with water, acid or paint and other dirt, which has a corrosive effect; 3. The clearance of the bearing is too small (the fit is not …